【 Manual Stationary Heating / static China 】06/12/2024

Manual Chinese stationary or static heating

Choose your screen model to see the manual, valid for Actecmax boilers

Under permanent construction.. I will be adding new models and updating the manuals little by little as I get them.

3
Manual Screen CH01
9

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

5
CH02 Screen Manual
7

Manual CH2 ⇒ Como purgar la bomba de Gasoil de la calefacción estática Este proceso es muy sencillo, but each screen has its own way of doing it, in this ...

Editor's Choice
3
CH03 Screen Manual
6

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

129
CH04 Screen Manual
56

LCD Negro (version 2018) (If the buttons beep when you press them, it is this other version) Before the first start, the heating must be vented. ( way ...

61
CH04 v2 Screen Manual 2023
17

Pantalla de inicio Al apretar el boton Ok se alternaran en este orden los siguientes datos: Visualización del reloj visualización de la temperatura ...

19
CH05 Screen Manual
6

LCD Negro (rectangular buttons) Before the first start, the heating must be vented. ( purged mode ) Once the heating is installed, you must ...

206
Manual Screen CH06
45

Manual stationary heating LCD Blue / LCD Dorado / LCD Rojo Estos tres modelos son iguales, They have some changes compared to the black LCD which ...

Editor's Choice
10
CH07 Screen Manual
7

Mismo manual que la CH6 El funcionamiento es igual a la version CH6, just change the layout of the buttons, and the color of the casing. You can access ...

1
CH08 Screen Manual
4

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

1
CH09 Screen Manual
4

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

0
CH10 Screen Manual
4

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

1
Manual Panel CH11
2

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

3
CH12 Screen Manual
7

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

147
Manual Pantalla CH13 (2019)
13

Como encender o apagar la calefaccion Para encender: We leave the power button pressed for 3 seconds. will light up. to turn it off: we leave ...

149
CH13 VEVOR Screen Manual (2022)
18

This new screen may cause confusion, thinking that it doesn't work or the screen is damaged, As soon as you connect it, it doesn't even let you raise/lower the power. ...

107
Manual Screen CH14
21

LCD ch14 Version 2019 (no universal) Como purgar la calefacción Una vez montada la calefacción hay que purgar el circuito, I have seen everything, from suck ...

16
CH15 Screen Manual
5

Before first start: Before starting you must check the battery voltage, If it shows less than 12.0v, it probably won't start., given that ...

0
Manual Screen CH16
1

Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...

19
Manual Screen CH17
7

LCD Negro (version 2019 hybrid) Como entrar en la configuración Hay que dejar pulsado el botón de configuración unos segundos. After that time ...

4
Manual Screen CH18
4

How to turn on the heating? With the heating off you have to press the button (on/off) what is roulette during 3 seconds. The display will turn on and ...

17
Manual Screen CH19
5

Features: This version keeps the screen off while the heating is off. No dispone de modo altura No dispone de programador No ...

21
Manual Pantalla CH20 YAH-A2105
5

Encendido y apagado Encendido Para encender la calefacción es muy sencillo, press the power button, after a little more than a minute, ...

54
Manual Pantalla CH21 Bluetooth
12

It is strongly recommended to check that the pump is set to 22ml, cases have appeared that have come as 16ml, which causes ...

106
Manual Pantalla CH22 Bluetooth YCSH
16

  Main features: Automatic height mode up to 5500m. Bluetooth auto connect/disconnect, qr code for ...

87
Manual Pantalla CH22 v3 Bluetooth YCSH
12

Disponible Aplicacion movil para Android y Iphone Enlace descarga Android Enlace descarga Iphone Puesta en marcha / First ignition / Apagado Para ...

9
Manual Pantalla CH23 GSM / YCSH SIM Card
0

Encendido Cuando esté apagada, press for 3 segundo el botón de encendido y apagado o haga una pulsación corta en el botón de encendido y apagado y la ...

Error screens

Heating display does not work?

The first thing you have to do, is to check if your heating control unit, match your screen.

If it is correct, go through the post about “error codes“.

Chinese LCD stationary heating error codes

Stationary heating regardless of origin, and from the manufacturer may fail, present failures and errors both when installing them, as after use. Today we are going to see…

FAQ / Chinese stationary heating questions

Here you will find countless questions and answers, starting from the model to choose, passing by where it will be installed, how to do it, doubts, configuration questions, spare parts the homologation process, etc etc.. Go on…

How to install stationary heating at home

How to connect the heating at home? It doesn't matter what model you have, whether it is normal, or the portable version, you only need diesel, and a power supply, don't commit…

  1. GREAT ESTEBAN It's the best I can read. I'm going to have it and install it and I'll report to your great command. Best regards

  2. My problem is that it starts up with a voltage of 13v and as it is working the voltage drops little by little to less than 10v, a little white smoke comes out and turns off giving the F10 error, my battery is in bad condition?, However, I turn on the refrigerator and it drops to 11.4v and it works. What could be wrong???

    • Hello Julio, Has it ever worked for you?, or is it a new installation? It looks like a voltage drop or a sulfated battery.. It has always run at 11.4v with the refrigerator? If the heating has previously been working well, and with the refrigerator you had 12v or more, I would opt for the bad battery.
      On the other hand, if it is a new installation, it could be due to insufficient cable section or a bad connection somewhere..
      Greetings.

  3. Hello Esteban, I hope you are doing well. Everything perfect with the heater with the plumbing 75. Here it was already cold. Is it advisable to empty the system of diesel until it is used again?? Is it ever necessary to run it until the frequent use season returns?? As always, THANK YOU for your responses.. Best regards

    • Hi Felix., I'm glad everything is fine! It is not necessary to empty the diesel circuit, but if the cold comes back in let's say 8 months.. yes in 4 You turn it on to renew the diesel in the circuit much better, with what to start and this 5/10 min is more than enough.
      Greetings!

  4. I will do it this way Esteban. GRACIAS. Hello2

  5. hello,
    I turn on my heating for the first time and the LCD screen (negra) no button responds.
    you know what i can do?

    • Hello Toni, it has never worked? maybe it came defective, or it has been hit and damaged.
      If it is new, write to the seller and ask for a replacement screen, or you can buy it, they are cheap, right now on ebay €4.89. Here I leave you some links.
      Greetings.

  6. Hola, I just started my heater 5.000 kw in a small boat and I am very happy, because it warms wonderfully. My question is about whether there is a possibility of turning off the LCD panel, since we only use the boat on weekends, but during the week I imagine that it continues to consume the battery. Greetings.

    • Hola, Indeed, the heating off consumes battery, it's little, But if you do not have a solar panel on the boat, it is best to remove the fuse., or install a minimum 15a switch. Something similar to this: https://amzn.to/2qcFcMp As a drawback, When you cut off the power, you lose the time, but it is very easy to put back.
      Greetings.

  7. Thank you very much for the response Esteban., At first I'm going for the switch.
    Greetings,

  8. Hola, I would like to know if there is a controller with a Chinese remote compatible with the webasto airtop 2000stc.

    • Hello I'm sorry, but neither the controls nor the screens are compatible with webasto or eberspacher.

  9. Hello Esteban, Do you know any Chinese gasoline heating?
    My van is not diesel…
    Gracias

  10. Good night. First of all, congratulations for the page. All the information there is is very valuable given how little information there is about them.. I have a 5KW heater and so far I am very happy. My question is the following. In some European heating models, There is the option of running the fan independently of the heating so that in summer air enters from the bottom of the van, which is usually colder, and generates a small current that improves the thermal sensation.. Is there this option in Chinese heaters? If not, it occurred to me to bypass the fan, but in order not to mess around, I prefer to find out.. Thank you very much in advance!

    • Hello, if a heater draws air from the bottom of the van, The only thing that will happen is that you will get smoke from the combustion that will be very close.. For me it is a mistake that it is like this, should recirculate the air inside.
      Answering your question, you can bypass the temperature probe, The heater will think it is hot and will turn on the fan.. It would be the opposite of what it says here.