How to lower the power of a Chinese stationary heater

How to convert a 5kw static heater into 2kw




diesel heater parking heater lcd static heating stationary heating identification buttons

 

Lately it is difficult to get a 2kw heater because the Chinese sell you a 2kw one and in reality they send you a 5kw one..

Or simply due to lack of knowledge and price, you bought the 5kw one because it was cheaper., and you get hot in your vehicle.

How to identify what power my Chinese static heating is?

stationary heating measurements china size 2kw 5kw differences

It is very simple, The 5kw one is approximately 38cm long while the 2kw one is about 32cm long..

Once the model we have has been identified, you have to get into the matter, and let's see the process we have to follow, I leave you a series of screenshots with the steps to follow, Afterwards you will only have to enter the information that I leave you below.

Step-by-step guide to reduce or limit the heat capacity of Chinese stationary heating.


If you don't understand it with the images, maybe it will be more comfortable for you see it on video The values ​​in the photos ARE NOT VALID and in the video neither, Continue reading the page below according to heating model.

 

Configuration to go down from 5kw to 2kw:

  • 1.3 hz
  • 3.5 hz
  • 1700rpm
  • 4500rpm
  • 12V
  • SN-1

Although it can be done, and everywhere they will tell you that you can get off.. This is not going to solve your heat problem.. because you will always have it at a minimum, and you can't do the least “understand it” only the maximum that does not affect you… even so, capacity at 2kw has more drawbacks than benefits, in the long run as the combustion chamber does not reach the optimal temperature when it starts, It will not burn the possible carbon that will be created little by little., and you will end up having to take it apart to clean it, so I recommend that you not lower it to 2kw, or that you directly change it for a model of 2kw.

If it has already filled with carbon.. come by here and see how to clean it.

Configuration to increase power from 5kw to 8kw: (not recommended)

  • 1.3 hz
  • 5.5 hz
  • 1700rpm
  • 4500rpm
  • 12V
  • SN-1

Power can be done, although it is not recommended, It's like in the previous case, you are putting in more diesel than necessary, depending on where you use/mount it there will be no problem, but in certain locations (height) can cause carbon deposits in the long run.

Here I leave you a video to know how to clean it.

Configuration to reduce the power to the minimum to 2kw:

  • 0.8 hz (0.8 only in 2kw heaters)
  • 3.0 hz
  • 1500rpm
  • 4500rpm
  • 12V
  • SN-1

 

All configurations are height-ready, and be able to operate at more than 2000m except 8kw.

  1. Hola!
    I have a question about taking the heating from 5kw to 2 kw, performance will be affected? I mean if it can present problems in the long run.

    Gracias!

    health!

    • exist 3 different pumps.. for what there is 3 different scenarios, Double depending on whether you lengthen the exhaust or not.. therefore, I would tell you that the first value, You will adjust them according to the lines that light up on your LCD screen, try to adjust it until it stays the first red stripe lit, and you won't have any problems.