Manual Screen CH19

Features:

This version keeps the screen off while the heating is off.

  • Does not have height mode
  • Does not have a programmer
  • Does not have thermostat mode, just for power

Activate Purge Mode

You have to press + of 5 the configuration button repeatedly (top left sprocket).

A counter will appear 60 seconds, upon reaching 0 will stop. If the up key is pressed before the end, gets back to 60.

The remote control

  • A: ON to turn on the heating
  • B: OFF to turn off the heating
  • C: + Increase power
  • D: – Lower power

How to associate the remote control

With the power disconnected, we press up arrow + Down arrow, we connect the power, pistol 3-5 times and it will come out “5-7R” Then press button B on the remote control / Off / turn off and it will be associated

View screen data

We can see different data on the screen by pressing the OK key, we will see:

  • Voltage
  • Temperature
  • Power

How to turn on the heating?

With the heating off you have to press the ON button once, without maintaining, after the start-up phase which lasts about 10 minutes, the heating will be set to medium power indicating on the screen 3.0 HZ, We can increase or decrease the power by pressing the up or down arrow.

How to turn off the heating?

being on, press the button “off” during 3 seconds, will enter the cooling phase, which will last approximately 10 minutes, NEVER turn off the power before it turns itself off..

How to adjust the power

This version of the screen only has 3 powers.

  • Minimum 1.0Hz
  • Half: 3.0 Hz
  • Maximo 5.5 Hz

 

Error codes

This version has a switchboard that only works for this screen.

FAILED / ERRORError code on the screenSolution
Diesel pump failure E-01Check connection and wiring of the pump, yes that's fine, connect it to 12v to see if the electromagnet works
Glow plug failureE-02Check the spark plug, and wiring, not detected or shorted
Engine failure E-03Check motor connection, the defective hall sensor.
Sensor TalumE-04Check the sensor
Low Voltage E-05Change from 24v to 12v in settings, o de 12v a 24v.
High Voltage E-06Connected to incorrect voltage, check power supply
LCD control connection failure E-07Data line (cable azul) of the control cut, the command disconnected / defective
Heating unit overheatingE-08Clogged air outlet
Fallo sensor HALLE-09Hall sensor does not detect engine revolutions
Flame detection failureE-10Air or lack of diesel in the fuel circuit, Defective temperature sensor or poor wiring connection.
OverheatingE-11Obstruction in the air inlet or outlet
Decrease in temperatureE-12Sudden drop in temperature, due to wind or lack of diesel
---E-13---
Diesel flow failureE-14---
Heat flow faultE-15---
Engine revolutions failureE-16---