Features:
This version keeps the screen off while the heating is off.
- Does not have height mode
- Does not have a programmer
- Does not have thermostat mode, just for power
Activate Purge Mode
You have to press + of 5 the configuration button repeatedly (top left sprocket).
A counter will appear 60 seconds, upon reaching 0 will stop. If the up key is pressed before the end, gets back to 60.
The remote control
- A: ON to turn on the heating
- B: OFF to turn off the heating
- C: + Increase power
- D: – Lower power
How to associate the remote control
With the power disconnected, we press up arrow + Down arrow, we connect the power, pistol 3-5 times and it will come out “5-7R” Then press button B on the remote control / Off / turn off and it will be associated
View screen data
We can see different data on the screen by pressing the OK key, we will see:
- Voltage
- Temperature
- Power
How to turn on the heating?
With the heating off you have to press the ON button once, without maintaining, after the start-up phase which lasts about 10 minutes, the heating will be set to medium power indicating on the screen 3.0 HZ, We can increase or decrease the power by pressing the up or down arrow.
How to turn off the heating?
being on, press the button “off” during 3 seconds, will enter the cooling phase, which will last approximately 10 minutes, NEVER turn off the power before it turns itself off..
How to adjust the power
This version of the screen only has 3 powers.
- Minimum 1.0Hz
- Half: 3.0 Hz
- Maximo 5.5 Hz
Error codes
This version has a switchboard that only works for this screen.
| FAILED / ERROR | Error code on the screen | Solution |
|---|---|---|
| Diesel pump failure | E-01 | Check connection and wiring of the pump, yes that's fine, connect it to 12v to see if the electromagnet works |
| Glow plug failure | E-02 | Check the spark plug, and wiring, not detected or shorted |
| Engine failure | E-03 | Check motor connection, the defective hall sensor. |
| Sensor Talum | E-04 | Check the sensor |
| Low Voltage | E-05 | Change from 24v to 12v in settings, o de 12v a 24v. |
| High Voltage | E-06 | Connected to incorrect voltage, check power supply |
| LCD control connection failure | E-07 | Data line (cable azul) of the control cut, the command disconnected / defective |
| Heating unit overheating | E-08 | Clogged air outlet |
| Fallo sensor HALL | E-09 | Hall sensor does not detect engine revolutions |
| Flame detection failure | E-10 | Air or lack of diesel in the fuel circuit, Defective temperature sensor or poor wiring connection. |
| Overheating | E-11 | Obstruction in the air inlet or outlet |
| Decrease in temperature | E-12 | Sudden drop in temperature, due to wind or lack of diesel |
| --- | E-13 | --- |
| Diesel flow failure | E-14 | --- |
| Heat flow fault | E-15 | --- |
| Engine revolutions failure | E-16 | --- |