【 Manual Stationary Heating / static China 】06/12/2024
Manual Chinese stationary or static heating
Choose your screen model to see the manual, valid for Actecmax boilers
Under permanent construction.. I will be adding new models and updating the manuals little by little as I get them.
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
Manual CH2 ⇒ Como purgar la bomba de Gasoil de la calefacción estática Este proceso es muy sencillo, but each screen has its own way of doing it, in this ...
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
LCD Negro (version 2018) (If the buttons beep when you press them, it is this other version) Before the first start, the heating must be vented. ( way ...
Pantalla de inicio Al apretar el boton Ok se alternaran en este orden los siguientes datos: Visualización del reloj visualización de la temperatura ...
LCD Negro (rectangular buttons) Before the first start, the heating must be vented. ( purged mode ) Once the heating is installed, you must ...
Manual stationary heating LCD Blue / LCD Dorado / LCD Rojo Estos tres modelos son iguales, They have some changes compared to the black LCD which ...
Mismo manual que la CH6 El funcionamiento es igual a la version CH6, just change the layout of the buttons, and the color of the casing. You can access ...
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
Como encender o apagar la calefaccion Para encender: We leave the power button pressed for 3 seconds. will light up. to turn it off: we leave ...
This new screen may cause confusion, thinking that it doesn't work or the screen is damaged, As soon as you connect it, it doesn't even let you raise/lower the power. ...
LCD ch14 Version 2019 (no universal) Como purgar la calefacción Una vez montada la calefacción hay que purgar el circuito, I have seen everything, from suck ...
Before first start: Before starting you must check the battery voltage, If it shows less than 12.0v, it probably won't start., given that ...
Manual todavía no disponible O porque no he podido conseguirlo, or because I haven't translated it yet. The website is updated almost daily, little by little it will go away ...
LCD Negro (version 2019 hybrid) Como entrar en la configuración Hay que dejar pulsado el botón de configuración unos segundos. After that time ...
How to turn on the heating? With the heating off you have to press the button (on/off) what is roulette during 3 seconds. The display will turn on and ...
Features: This version keeps the screen off while the heating is off. No dispone de modo altura No dispone de programador No ...
Encendido y apagado Encendido Para encender la calefacción es muy sencillo, press the power button, after a little more than a minute, ...
It is strongly recommended to check that the pump is set to 22ml, cases have appeared that have come as 16ml, which causes ...
Main features: Automatic height mode up to 5500m. Bluetooth auto connect/disconnect, qr code for ...
Disponible Aplicacion movil para Android y Iphone Enlace descarga Android Enlace descarga Iphone Puesta en marcha / First ignition / Apagado Para ...
Encendido Cuando esté apagada, press for 3 segundo el botón de encendido y apagado o haga una pulsación corta en el botón de encendido y apagado y la ...
Heating display does not work?
The first thing you have to do, is to check if your heating control unit, match your screen.
If it is correct, go through the post about “error codes“.
SOLUTION the heating fan does not turn off
Why does the fan not turn off?? It is not common but you may find that one day you go to your vehicle and find the heating fan on.…
Chinese LCD stationary heating error codes
Stationary heating regardless of origin, and from the manufacturer may fail, present failures and errors both when installing them, as after use. Today we are going to see…
SOLUTION to altitude sickness Chinese stationary heating LCD
IMPORTANT When to set this height setting? The answer is ALWAYS there are countless different pump models., and the sellers do “KITS” They buy the pump in a…
【 Analysis & Review 】 Chinese stationary or static heating 12v 2020
Stationary heating There is very little information about this type of heating, which are gradually becoming popular due to their low price. To this day it has already been…
3 Ways to heat water with your Chinese stationary heater
You have been asking me for months how to heat the water in the camper van or motorhome easily., simply and economically with a Chinese stationary heater. Today the…
FAQ / Chinese stationary heating questions
Here you will find countless questions and answers, starting from the model to choose, passing by where it will be installed, how to do it, doubts, configuration questions, spare parts the homologation process, etc etc.. Go on…
SOLUTION ? To the dry Throat with your Chinese stationary heating
As a fan of the camper world, If you have come this far it is because you have a problem, or do you think you could have it in the future. And that problem is nothing else…
How to lower the power of a Chinese stationary heater
How to convert a 5kw static heater into 2kw Lately it is difficult to get a 2kw heater because the Chinese sell it to you in 2kw and in reality you…
How to install stationary heating at home
How to connect the heating at home? It doesn't matter what model you have, whether it is normal, or the portable version, you only need diesel, and a power supply, don't commit…
⇒ How to APPROVED static or stationary heating?
How to approve a Chinese YCSH heater? If you are thinking of installing a stationary heating in your vehicle, whether it is a recognized brand like Webasto Air Top 2000 ST o Eberspächer…

Hola, I have the blue LCD on my portable heater and the blue remote control with two buttons only, I have tried with your instructions to pair the remote with the heating but unfortunately nothing happens so as you recommend I will have to complain to the seller to solve the problem or send me another remote to see if there is any luck and I can use my heating without having to get up the bed to turn on and/or off.
Hello Eloy the Blue command, only works with red remote control and the remote that looks like a garage with 2 buttons, it's for him LCD negro.
Unfortunately you are not the only one who has been sent the wrong controller, try to complain, what you get will be welcome.
Hello Esteban, Do you know any Chinese gasoline heating?
My van is not diesel…
Gracias
Esteban,
Thank you so much, I have already claimed the Chinese.
There is no choice but to wait and in the meantime ask for a red remote control that does work with my Blue LCD..
Greetings
Good morning;
I have a Chinese stationary heater and I have problems with it, it stops me.
I have tried it when I just bought it and it works but when I installed it in the van it stops, This weekend it was very difficult for me to get heat, I imagine that because the engine was unprimed and I could see that some air was entering the diesel circuit that passes through the pump., The air heats up a little but soon stops..
Could that be the problem, that the between area? They have told me about installing a non-return valve., do you think it is the solution?
All the best
Hola, to find out if the problem is really in the connection to the tank (I imagine that with a T) remove the diesel tube from the tee, and take the diesel from a bottle, That way you will know if the fault is with the heating, or fuel supply.
Yes it works with the bottle, you can try with the non-return valve, although I don't think that is the solution, since the pump itself acts as a non-return valve.
The most advisable thing to avoid having problems is to put a espadin.
Greetings
Good morning;
Thank you very much for your response, but I have the heating connected to the tank gauge with a spade.
They have told me about the non-return valve because I have observed that the pump allows some air to pass through and I do not know if the valve is 100% reliable against the passage of air.
Hola, if you have sprat, you don't need a backstop at all, the pump itself takes care of that. If air is entering you, it is through a cuff., either because of being lazy, or too tight and deformed at any of the joints.
Ok, Thank you very much for your answer. I'll try changing the clamps to see how it goes..
I have seen that a little diesel is leaking at the inlet of the hose to the heating diesel filter., I have put two clamps on it but a drip keeps failing, what would I do, I would change the filter (the piece)?
So that it has a little more body, dale 3/4 turns with teflon, You will surely fix the gout, although look carefully at the filter, lest it has a small crack and it is not coming out through the union, but for her.
Aside from the filter issue, I have the problem that the heating stops and I don't know why it could be, At first I attributed it to the entry of air into the circuit but that is not the case., because when changing the clamps I noticed that there is no longer any air. It works a little, a few minutes, dirty area, burns well but goes out,… Which may be due? The management is analogous.
Seeing that the air problem is already solved, You should see what error you are getting.. You should tell me if it is the E-05 (overheating) o he E-08 what is combustion failure, so we can find the problem and give you a solution.
Greetings.
I have a manual thermostat, So I can't know what error it is giving me..
Hello again Esteban., doesn't stop flashing, It starts flashing when the pump stops working and does not stop flashing until it does the cooling cycle, but from 5 min. blinking
I would need you to make a video so I could see the blinks..
You can upload it to YouTube and put the link here, in the group of facebook, But the truth is that I don't know how to give you an answer..
I have received the heater on offer and it comes perfectly. 2.2kw without added customs cost, digital control and remote control. I am happy, when I install it I will tell you. Thanks for your advice. Greetings
Great, I am glad that it arrived complete and without customs. If you dare, when you ride it, upload a photo to the group facebook, or you can get ideas before assembling it yourself. Greetings.
Hello, I'm desperate, I bought one of these stationary and it came with a very small LCD remote control, all in chinese, an odyssey, I don't know what each mode indicates, anyway… I managed to start it, it brought out warmth, but after a while it stopped, So I bought a Black LCD controller. (round buttons) and there is no way for it to start, it does not work, an icon simply lights up between the button “OK” and the heating diagram, orange in color and with arrows marking direction (rotation). Do you have any ideas????
Hi Jordi, So without seeing it it is difficult to know exactly what is happening..
I would need you to make a video, from the moment you turn it on to see how it behaves and if it gives any errors or what happens.
You can upload it to the group of facebook, or upload it to youtube and send me the link to review it.
I'm waiting, greetings.
Hello Esteban, First of all THANK YOU VERY MUCH FOR THE INTEREST!!.
I have uploaded it to Youtube, this is the link: https://youtu.be/At_35kW7Pks
Let's see if you can look at it and find the solution.!
Thank you very much once again!!
Vale, We talked about it there in the Facebook group post. It is This is the link to the post in case the same thing happens to someone..
Hola, Does anyone know how to purge with the blue remote??
I have tried pressing ok and the left arrow at the same time and nothing, and with the right arrow neither.
Hola, on the blue screen you have to press the settings key + right arrow, It is different from the black one that is Ok + Arrow down
Gracias, for the info, but I don't know what I'm doing wrong, it doesn't work out, I keep the 2 buttons pressed at the same time for more than 10 seconds, but nothing happens, nothing changes on the display.
Hola, you don't have to hold it down, just press the gear button at the same time + left arrow less than a second and appears “H of” With the little arrows you change it to ON and it begins to purge.