CH04 v2 Screen Manual 2023

Article index

Home screen

By pressing the Ok button the following data will alternate in this order:

  1. Clock display
  2. room temperature display
  3. display of battery or power supply voltage
  4. display of the selected power or temperature
  5. combustion chamber temperature display
  6. error code display in case of failure.

Home screen with heating off

  • power button: short press to turn on, and the panel shows ON.
  • Up Button: temperature / march +
  • Down Button: temperature / march –
  • Confirm Button: cyclically changes displays.
  • Settings Button: set parameters.

Home screen with heating on

  • power button: long press to power off and the panel shows OFF.
  • Up Button: temperature / march +
  • Down Button: temperature / march –
  • Confirm Button: cyclically changes displays.
  • Settings Button: set parameters.

 

Remote Control Code Pairing Instructions

With the heating off

Simultaneously press the setup button and the up button to enter the pairing screen, the panel will display -PE-; Press and hold the ON/OFF button on the remote control to pair the remote control. After the code pairing is completed successfully, it will exit automatically or press the power button again to exit. If you don't, It will only come out after 20 seconds.

Operating modes “by power” o “thermostat mode” with automatic stop

You can change the mode with the heating off or on by following these steps:

  1. Press and hold the up/down keys simultaneously to toggle between mode “power” or the way “thermostat”. The screen will show “27 ℃” and it will flash. Press again to switch to power mode, and the interface will show “P-01” (this is the default mode).
  2. When the heating is on, Press and hold the ON key on the remote control for 3 seconds to switch between power modes / thermostat. *You have to wait more than 3 seconds between changes.

 

purged mode

With the heating off

Simultaneously press the setting button and the down button. will show the time “020”, For example. Press the setting button then up to increase purge time or down button to decrease it. (The range is up to 999 seconds). Short press the confirmation button to start/stop pumping.

Press the power button to exit, or it will automatically exit if you do not press anything for 20 seconds.

Parameter configuration

Press and hold the setting button with the heating off.

Clock settings

The initial clock display is “00:00” and the first blank space flashes. Press the up/down button to adjust the number, To go to the next number you must press the configuration button until completing the 4 fingers.

Scheduled Start Settings

The programmer's initial display is “00:00” and the first blank space flashes. Press the up/down button to adjust the number, To go to the next number you must press the configuration button until completing the 4 fingers.
It's a countdown, where you indicate the hours and minutes, and it will turn on when it reaches 0.

Scheduled Shutdown Settings

The initial time display is “00:00” and the first blank space flashes. Press the up/down button to adjust the number, To go to the next number you must press the configuration button until completing the 4 fingers.
It's a countdown, where you indicate the hours and minutes, and it will turn off when it reaches 0.

Password entry

Initially, sample “----” and the first blank space flashes. Press the up/down button to change the number and then press the confirm button to confirm and move to the next blank. The subsequent numbers are set in sequence and finally press the confirm button to move to the next setting when the password is correct.

The password is: 1234

P1H2 display in internal configuration interface

The first “P” indicates manual mode, the first “T” indicates constant temperature mode (power mode) and the first “A” indicates auto start/stop mode. After configuration, Short press the confirmation key to move to the next parameter.

In the second blank, sample “1” for accessories 12V y “2” for accessories 24V. Press the up/down button to switch to 24V accessories. 12V and 24V accessories can be changed cyclically. After configuration, Short press the confirmation button to move to the next setting.

In the third blank, sample “H” to 5KW y “L” to 2KW. Press the up/down button to switch to 2KW. 5KW and 2KW can be changed cyclically. After configuration, Short press the confirmation button to move to the next setting.

In the fourth blank space, sample “2” for the pump 22 mL,8” for the pump 28 mL y “1” for the pump 16 mL. Press the up button to switch to pump 28 mL and the down button for the pump 16 mL. All three types can be changed cyclically. After configuration, short press the power button to exit, or the setting will automatically exit if you do not press for 20 seconds.

Activate mode “automatic start/stop” in thermostat mode

Select auto start/stop mode, Press the power button to enter the boot temperature setting interface and the initial display is “ON: 25”; Press the up/down button to adjust the flashing position, Short press the confirmation key to enter the next parameter, set the values ​​in sequence and then short press the power button to exit the setting (range: 15 ℃ – 35 ℃); after returning to the main screen, Press the up/down button to modify the auto shut-off temperature;

Use: Automatic shutdown occurs when the ambient temperature is higher than the shutdown temperature; after automatic shutdown, when the ambient temperature is lower than the start temperature, will start automatically.

How to turn off the screen

Heating off: The screen will turn off completely after not receiving any press for more than 5 minutes.

Heating on: The screen will turn off after not receiving any press for more than 5 minutes. If the screen is off, There will be a flashing light as an indicator and it will show a “padlock”. Press any button to wake up the screen.

HEIGHT MODE

Unfortunately this heater does not have a height mode., The manufacturer indicates that it should work well up to 1800m, but it may not be enough for you.
All is not lost, after doing several tests, having pump 22ml can configure as if it were a 28ml pump, In my tests the combustion chamber was around 110/120º at the minimum and at the maximum around 170º, enough to work well at any height.. According to circumstances, mounting, etc. those values ​​could vary.
If with that trick you had carbon problems, the solution would be to change screen + switchboard for the version “universal” Yes, it allows you to configure parameters, and configure it to height.

FAILED / ERRORError code on the screenSolution
Low voltageE-01Voltage per
low 10v or 18v ​​if it is the 24v version
High voltageE-0232v in the 24v version
BujiaE-03/F1Short circuit in the spark plug
E-03/F2Open circuit
E-03/F3
Replace
diesel pumpE-04/F1Short circuit
E-04/F2Open circuit
OverheatingE-05It has exceeded 260º obstructed air circuit
engine failureE-06/F1Short circuit
E-06/F2Open circuit
E-06/F3
Hall sensor does not detect the fan
Screen connection failureE-07Check wiring and that the connector is well connected
Flame failureE-08Air in the circuit, obstruction or lack of fuel
Temperature sensorE-09/F1Short circuit
E-09/F2Open circuit
Ignition failureE-102 failed boot attempts, check that you get diesel, striped cuff, pump the blocked circuit
Room temperature sensorE-11Open or short circuit
Control unit overheatingE-12The control unit is above 100º air inlet or outlet blocked or damaged control unit