Stationary heating regardless of origin, and from the manufacturer may fail, present failures and errors both when installing them, as after use.
Today we are going to see the typical failures of this type of heating and how to solve them..
Table with error codes and solution for Chinese static heating, actecmax, winfull, ycsh
| FAILED / ERROR | Error code on the screen | Solution |
|---|---|---|
| It is not an error | E-00 | Everything is going well |
| Low Voltage | E-01 | Change from 24v to 12v in settings, o de 12v a 24v. |
| High Voltage | E-02 | Connected to incorrect voltage, check power supply |
| Glow plug failure | E-03 | Check the spark plug, and wiring, not detected or shorted |
| Diesel pump failure | E-04 | Check connection and wiring of the pump, yes that's fine, connect it to 12v to see if the electromagnet works |
| Heating unit overheating | E-05 | Clogged air outlet or inlet or abnormal fan speed |
| Engine failure | E-06 | Check motor connection, the defective hall sensor. |
| LCD control connection failure | E-07 | Data line (cable azul) of the control cut, the command disconnected / defective |
| Flame detection failure | E-08 | Air or lack of diesel in the fuel circuit, Defective temperature sensor or poor wiring connection. |
| Temperature sensor failure | E-09 | Sensor shorted, cut or bad cable |
| 2 Failed boot attempts | E-10 | Diesel does not arrive, voltage drop in the power cable, soot in the combustion chamber |
Solution guide for the most frequent problems in a Chinese stationary heater
Error E-01 Low voltage
It is one of the most common problems. When the heating comes, many times it is configured incorrectly and this error appears.
It is not because the battery is low or discharged., simply because it is configured at a different voltage than the one you have connected. If your battery or power supply is 12v your screen will be set to 24v, goes into, modify it and it will disappear.
This error can also appear due to low battery or voltage drop., for not using 6mm cable or making a bad connection. Check the manual assembly if you need more information.
How to know if the battery is in good condition?
Press the heating start button, immediately when the spark plug icon is illuminated on the screen press the OK button repeatedly until it shows the voltage of the battery.
If the voltage is 12.3v or higher, the battery is good.
If it is between 11.8v and 12.3v the battery would still be acceptable.
If it is less than 11.8v, it is a sign that the battery is not in good condition., it would have to be loaded.
Below 9.5/10v it will give you error E-01.
Solution:
- Charge the battery 100%
- If you still have the problem, after charging it, replace the battery.
Error E-02 High Voltage
Recently (November 2022) This error is appearing in many new heaters, especially brand ones. “VEVOR” This error appears because a 6mm cable is not used or a battery is in poor condition and the voltage drops below 9/10.00v at startup. (low voltage).
Although this error occurs because there is +15v in the battery, solving that., it would work properly again.
It needs a battery in good condition to work., and if it is used in a home, A power supply of at least 15/20ah is recommended. 30ah Any transformer you have at home won't work..
Error E-03 Spark Plug Failure / preheater
To check the spark plug, have 2 possibilities.
- Measuring its internal resistance with a multimeter should read between 0.6ohm y 1.0 ohm.
- Connect it to 12v for a few seconds, and I emphasize a few seconds because if we are much longer you will be burdened… It should be red hot.
If you are going to take it out you will need It is useful.
Many times, This error can appear due to Low Battery / tension fall, go to the menu where you see the battery voltage, turn it on, If it drops below 11.5v, surely that is the problem., charge your battery, check the wiring, Replace it with a thicker 4/6mm one and try again., If the voltage continues to drop 11,5 Consider replacing the battery and checking all the connections carefully if you think it is okay because something is happening..
If everything above is correct and the error continues to appear,-03 The problem is in the circuit that detects the spark plug., The solution is to replace the switchboard
Error E-05 Overheating
This error is quite common, It usually occurs due to poor installation.
To avoid this error, or solve it you have to avoid sharp curves, or tubes that are too long both at the entrance, as in the hot air outlet.
Due to lack of knowledge, pronounced curves are usually made at the hot air outlet..
Solution:
- To avoid this problem. You should avoid bending the hot air outlet tube at least 10cm from the heater., and that the curve was not higher than 90 degrees.
- You can check if the problem really is that, disconnecting the tube completely and leaving a free way for air circulation.
Error E-06 engine failure
If it is nueva It is most likely that during transport the axle has been displaced due to an impact., and the propeller is touching against the control unit or against the casing. If you try to turn it and it is blocked, you know why it is.
You can adjust it by hand, you don't need any type of tool, it's going hard, but it moves. With this image you can get a clearer idea of the procedure to follow..
You also might not have trimmed the floor properly. (carpet, madera etc..), and when the plastic casing of the heater touches the floor it deforms and the propeller rubs or blocks.. Or you have overtightened the mounting screws. Just try loosening them a little., dismantle it, and trim the ground well.
It is also possible that the wiring has poor contact, the motor connector is loose, or the battery voltage is insufficient to make it rotate at the revolutions necessary for starting. (Check that when you press on, the voltage does not drop below 11.5v.) If this happens, change the power cable for a 6mm one., the one that goes from the battery to the fat heater connector, replacing the original cable.
It may also be the case that it is the other way around., the propeller rotates normally but it is not detected, Instead of extracting the propeller it would be the opposite to push it (without going over) so that the control unit sensor detects it.
If it has already been working previously, and it doesn't touch the problem, it's almost certainly the battery., if you have relay, Turn on the van's engine and you'll see quickly if it's solved.. Also, due to wear the propeller may now be touching the casing, A slight adjustment should be enough to solve it..
Solution:
Check wiring, and that the connector connection is in good condition.
Move the propeller shaft by hand, This should rotate very smoothly., and without friction of any kind.
It goes hard, she stopped, we take off the lid, y propeller pull outward or inward.
Check the battery voltage by pressing the OK button repeatedly until it shows the battery voltage. It must always be higher than 11.5v, because if it drops below 11.5v at startup it will almost certainly not start, lack of voltage also causes this error, in addition to others like the E-04.
Sensor Hall, another reason why we have error E-06 It happens especially if we dismantle the control unit to tinker with it.…….. Then when you mount it, the sensor is outside the hole, which keeps it in the correct position.. These components are usually crushed and left out of place., which causes the control unit to not detect the engine RPM.
Error E-07 Communication failure between screen and control unit
The first thing would be to check if your heating has the appropriate control unit for your screen., There are already several cases in which I have found that due to the manufacturer's error, they mount a screen incompatible with your switchboard at the end of this post, I leave you the relationship between screen & switchboard so you can check it.
Another possible cause of this error, is that at some point in the wiring, the blue screen wire does not make good contact, take out the connectors, put them back, put some contact cleaner on them if necessary, or measure the voltage between the blue and black wire, It should mark around 3v.
If 3v reaches the blue wire, or the screen is incompatible, or is it damaged, you would have to replace it here you can find the spare part.
If the voltage is 0, The fault could be in the switchboard or in the cabling.
If it has never worked, It could also be due to confusion on the part of the seller and he has installed a screen or control unit that is not compatible with your screen., When this happens it is usually because you have the CH4 screen, CH14 o CH17. Look at what switchboard you have and compare it with the photos at the end of this page where I tell you which screen it is compatible with.
Error E-08 Lack of flame, or combustion failure ( White smoke )
It may seem obvious.. but you have verified that you have diesel??? How many times have I found that the problem was that?. :p
Without a doubt this error is more common in this type of heating., occurs when a warm temperature comes out through the air outlet, and through the exhaust pipe, a big white smoke.
It may be due to an obstruction or difficulty in the passage of air in the exhaust pipe., muffler, due to poor assembly, too many curves on the circuit, soot in the combustion chamber or because you are at more than 1800m altitude without changing the setting or your battery does not have enough power to light the spark plug, or even that for some reason you have air bubbles in the fuel circuit.
The first thing is to modify the configuration for the height mode. In it 80% of cases solves the problem.
If you live at an altitude close to 1500m above sea level, It is possible that over time, due to poor combustion, soot has formed, which is why the heating has been working well for you until now..
Don't be alarmed by the smoke, especially if it has suddenly stopped working and it is getting inside you, the van is not waterproof, and making a cloud of smoke outside, somewhere it will end up entering inside even if it's just a little.
If the smoke thing has happened to you, It is not good to insist on restarting it without first solving the problem., since the diesel does not burn completely, creates carbon (more than you imagine) and little by little it floods the combustion chamber, making it difficult to start once the problem is solved..
If you have come this far, you've probably tried turning it on 20 times, your exhaust pipe is leaking diesel, the battery is shaking due to the consumption of the spark plug, and you have cursed the day you decided to save €800 by buying this Chinese shit.
Bueno, Don't worry, It is rarely a fault in the control unit or LCD control and you can solve it,
Causes:
Being at height, Due to poor combustion, carbon is created., it doesn't burn well, and the flame goes out, being impossible to turn it back on.
Solution:
- The first thing is to check the voltage: pressing the OK button repeatedly until it shows it on the screen, it should be higher than 12.3v with the heating off and higher than 11.4v once we turn it on., If it is lower, charge the battery, If it continues happening, replace it.
- Adjust the values of the control unit with the values that you will find here according to your heating model: Ver
Now we must test the ignition, Surely a lot of smoke will start to come out and we will have to make several attempts. If we notice a change in the sound, BINGO! we already have it.
It is totally normal that it does not turn on the first time, since it is flooded with diesel.
If the voltage is below 11,5 while turning on, y You can't get it to turn on test with the engine running.
If none of this has worked, your heating will be full of carbon, The air does not flow properly or is poorly assembled, then, You can try to clean it by putting pressurized air through the intake pipe and, if possible, then through the spark plug hole..
Yes after following this guide, still not working, powerful contact me and I will try to help you.
Error E-09 Temperature sensor failure
Causes:
Although it is a failure of the temperature sensor, It does not always have to be a failure of this, Most likely the power cable you use is too thin, you have lengthened it, have a bad connection, is rolled up on itself, or the battery is in bad condition.
For some of these reasons, the voltage drops below the minimum for starting 11.5v and can manifest itself by marking many errors that have nothing to do with them.. The reason is simple, That voltage already tells you that the battery is either discharged or dead and will not work..
Solution:
Check the wiring, all the points mentioned above, shorten the cable and leave about 10cm, and send him a cable as God intended, 6mm is advisable, it may seem like a lot, but we are working at 12v and not 220v here if it is stupid.
If you consider that all that is fine.. check the sensor cable, usually has 2/3 pins although only uses 2 cables, It could be that it was set incorrectly. (if you have 3 pines), what was loosed. You can measure its resistance with a multimeter, it should give approximately 60k at a temperature of about 21/22 degrees. About 17º it will be around 55/57k, This value will decrease depending on how cold it is at that time.
If you consider that the sensor is in bad condition, here do you have the spare part.
Error E-10 The heating has not detected heat in the 2 last boot attempts
Causes:
- LACK OF FUEL due to not being purged, or a cracked hose or filter
- Air in the fuel circuit
- Voltage drop in the power cable
- Low battery
- Clogged fuel pump
- Combustion chamber full of soot you can see here how to clean it.
Solution:
First you should check if white smoke comes out.. If smoke comes out, We rule out that the heating diesel pump is failing or that the diesel is not reaching it..
What voltage does your LCD screen indicate?? at standstill it should be higher than 12v (50% charging)
We press to turn on, the spark plug icon will illuminate, Low 11.5v? If it drops below 11.5v, it is probably the cause of the problem., since it will not have enough force to burn the diesel, and that's why white smoke comes out.
If all of the above is fine, maybe not configuraste and it's full of soot look how clean it.
At this moment the combustion chamber will be flooded with diesel., and dripping from the exhaust pipe, have patience, it will start and release a lot of smoke.
If NOTHING of what I have explained has worked for you, go to a gas station, and blow pressurized air into the intake tube, because it will be full of carbon.
Don't be tempted to remove the spark plug and connect it directly to 12V. (YOU WILL BREAK IT), If white smoke comes out it means it works, You will not be the first nor the last who has burned it doing that test., either when trying to remove it, or by overheating it.






Hello good, I can't start it, I have a 5kw Chinese stationary that I bought and at first it starts and marks the 20 min error 8, then from there error 10, and it doesn't start…..try it, a lot of smoke comes out, the diesel heater is full, but I don't know lame……purge the circuit well, I put it back together and the same, I tried it with the engine running and nothing, I dismantled it and blew through the intake and the same…..I don't know what to do anymore
Hola, have you set the height settings? In most of these cases, an extra supply of air solves the problem.
If it doesn't work, Tell me what voltage your battery shows (on the LCD screen before turning it on, and to the 40/50 seconds after turning it on) with the engine off. Greetings
I did set the height settings, and tomorrow I will confirm the voltage with the engine stopped, Yes, it's true that lately I've only been trying to start with the engine running.…..how does it fail me, to prevent the battery from falling…. The cable section is 2.5, just like the one that comes out of the heater, and I have it installed next to batteries, that at most there will be one meter of cable…..
Good morning, I have a Chinese stationary heater in a truck., It was working very well and two days ago it stopped and has not started again., it gives me error 10, I've looked at everything well and it seems like it wants to start and then it falls, If it smokes white but doesn't start, could you give me some advice?. Thank you very much in advance. All the best
Hello Marcos, you have it configured for height? If not, look at it. manual and configure it.
From what you say and assuming that the voltage that reaches it is fine., the problem is probably carbon, Put pressurized air through the intake to see if you can clean it., if after that it starts, when it's very hot, put air back in.
Good Esteban, nothing, shorten the cable, I added more section to the section up to the fuse box, and nothing! The voltage does not drop below 12.5 at the beginning and 12 after trying….blows a lot of smoke, try it, but it doesn't start! I have had the configuration you gave me since it stopped the second time.…..I don't know what to do anymore??
Hola, It's strange that it doesn't start unless it's full of carbon., Have you tried putting pressurized air through the intake pipe?? I would tell you hot but if it doesn't start.. try this other configuration: 0.9hz / 4.5hz / 2250rpm / 4500rpm /12v / SN-1
Hola, 2,5 it's not enough, but if you lengthen it.. you make it worse, It is best to cut it as short as possible and use another thicker 4-6mm.
If it drops below 11.5v that is the problem.
If it doesn't go down, put this configuration and tell me 0.8hz / 4.5hz / 1950rpm / 4500rpm /12v / SN-1
Nothing Stephen, with that I can't get it to start either….What else can I do?….
I already blew through the intake and there is no carbon……there can't be, It's new and I couldn't get it to start.
Hello Olmo, enter the group of Facebook and join the group, create a new post with your problem, and I would need you to make a video for me, that the behavior of the screen could be seen so much from the moment you start it, like the amount of smoke, the noise, etc.. to see if with photo/video I can identify what is happening.
But because of the symptoms, everything indicates that it has carbon, although it is new and should not have. It's very strange.
Greetings.
Thank you very much I will try.
Sorry, I think I wrote before on the site that wasn't…….I tell you my problem,I have a heater with a black remote control with square buttons and a rotating wheel.,well then,…..It starts fine but the pump drives at high speed and the burner icon comes on,during 5 minutes it emits a lot of white smoke but the air comes out hot,then lower the speed of the pump and the smoke comes out perfectly and the air continues to come out hot, although the burner icon is off ,It continues like this until the pump stops working and appears on the screen A-8 and turns off….At this point the lacalegaccion is very hot although it has an air outlet without a tube.,that is, it comes out without obstructions……I bought the black remote with round buttons to configure it but when I connect it I get error E-7 and it doesn't let me do anything…..Let's see if you can guide me please…….At the moment I just ordered the blue remote to see if there is something wrong with the black remote….Without further ado, greetings and I await your response.,thank you so much
Hola, E-7 is because the screen does not communicate with the control unit, but it's not clear to me what command you had at the beginning, It is? It baffles me a little about the square buttons and the fact that it also has a roulette wheel..
Without knowing exactly which is the original remote control, I can't tell you more. Greetings.
Hello Esteban,no,it's not that……I don't know how to attach a photo here….I'm a little negative about these things…..if you guide me how to do it,I upload it……I have a switch on so that the LCD is not on constantly,I don't know if it has anything to do with it…..The fact is that with the remote I have everything connects well and with the new one it says E-7……If you tell me where the communication failure between control and control unit could be, maybe I can solve it.,but I already told you that the one I have communicates well even with the switch…..Let's see if I can upload a photo
Join the group of facebook and you upload it there, It's much easier, even to speak
hello, I have a Chinese LCD stationary heater( the same as the starting photo), and sometimes when I start it it goes fine and other times I get the error code F-07 with a red flashing symbol. Due to the error code it is a communication failure, due to wiring failure.. I have removed the screen wiring connector ( 3 red wires, blue and black) directly soldering the cables and the problem persists, but I repeat only sometimes. I don't know if I should also cancel the motor connector.… what can it be??
Thank you so much
Hola, I have found some cases, that some 220v cable from the inverter, or the remote start cable of the inverter crosses with that of the screen and causes interference giving that error.
You say what happens to you sometimes?, See if it matches with the inverter turned on., let it not be for that reason.
Hola, what a great job you are doing mate! I congratulate you for your great contribution ??
My heating fails at 2dh, and I can't find the solution to the problem. What is happening to him???
Thanks in advance
Hi Jordi, I don't know that error, what model is it? enter the group of facebook and post some photos
Hello, good evening, I also have a heater. Last year I bought it and it was perfect, but this year I put it back in and it turns on but it doesn't heat up, it's warm and temperate. 4 minutes it turns off which could be?
it could be due to low battery, Cut the original cable and change it for a 6mm one (unless it is 50/100cm maximum from the battery) and try with the engine on, it could be that it was low on charge, It is the most common problem
Hello, I want to ask a question. The boiler starts with the fan on. 2 I try to do all the steps but when it flashes on the display that it should activate the fuel pump it does not send power and I get the error 04, I have tested the pump and it works well, Of the cables that must be connected, a light bulb was placed to verify that it emits current and it does not., the platelet fails ?
Hello Alejandro, If it looks like the switchboard has broken (transistor that controls the pump) It could also be that the cable is damaged somewhere., check it along with the connections, yes the cable is good, replaces the switchboard Greetings.