▷▷ What type of auxiliary battery to choose 【 Tips! 】

Specific auxiliary batteries for solar installations, second battery in camper vans and home vehicles.

In the market there are many types of batteries now I will make you a small summary.

Sealed lead-acid no maintenance and open batteries :

12V Acid Bathroom with Furgovw Maintenance

Most batteries are of this type and are characterized by having the two electrodes (positive and negative) immersed in a liquid electrolyte (A solution of distilled water and sulfuric acid).

Standard batteries have removable tapas to allow restoration of the electrolyte level, While sealed batteries (or no maintenance) They are made up of ventilation holes, what (in general) They cannot be removed and allow all the gas generated during the battery charge to disperse in the air outside the battery.

Therefore, Maintenance batteries are not totally sealed and it is also important to avoid overload, or the electrolyte will evaporate prematurely, causing a significant reduction in battery life.

 

Lead-acid batteries deep tubular cycle:

PLOME BATTERY ACCIDENT CYNETIC PLATE

The monoblock battery with tubular plate is especially indicated in systems that need very deep discharges.

The special construction of the 12V solar monoblock battery tubular allows to support continued downloads of up to the 80% maintaining its capacity and performance for many years. We have even 1200 Cycles in this download regime. If we need one 12V solar monoblock battery that lasts many years we must choose this tubular plate model.

Applications in which we must use a tubular monoblock battery.

It is recommended to use the 12V 240AH monoblock battery tubular en instalaciones con consumos moderados que aunque no requieran de muchas horas de autonomía van a efectuar descargas profundas y a intensidades elevadas de descarga. If we are going to install a fridge Throughout the year and we decided to mount monoblock batteries we should go to tubular models for its duration. Electric vehicles such as sweeps, Buggies de Golf, small elevators find on the tubular battery the perfect energy supply for its operation.

Tubular monoblock battery maintenance.

The only maintenance we must do to Monoblock batteries 12v tubular is periodically checking the water level. Depending on the use and discharges, greater or lesser water consumption will occur. As a general rule in a solar application we must review each 3 months the level while if we use them in an electric vehicle we will shorten this period in half.

Load of a tubular monoblock battery.

Para que la batería monoblock tubular funcione adecuadamente entregando toda su potencía por mucho tiempo debemos utilizar los valores de carga recomendados así como realizar ecualizaciones periódicas. The absorption load value for a battery of 12 tubular volts is 14.9v (2,48V/CLUD) While equalization must be done at least once a month in cycly uses at 16.2v (2,70V/CLUD)

AGM batteries (True):

bateria agm victron energy 12v

These types of batteries contain an agM solid electrolyte (Absorbed Glass Mat, which is a fine fiberglass impregnated with a solution of water and sulfuric acid) Among the electrodes.

These batteries have all the advantages of gel batteries, But they do not present their limits, since they can withstand a greater load current: The battery can be loaded as a standard battery.

Another important feature is that these batteries are “recombinant”, that is to say, Oxygen and hydrogen produced during load are recombined again generating water (with an efficiency superior to 90%) directly inside the battery, ensuring a very small loss of water throughout the life of the battery.

Gel batteries:

bateria gel ultracell

Gel batteries contain gelified electrolytes (obtained by adding silica gel): This does the electrolyte (Acid solution of distilled water and sulfuric acid) solid and jelly.
The main advantage of this type of batteries is that they cannot release acid, Even if they get upside down or if your box is broken.
The main advantage of this type of batteries is that they cannot release acid, Even if they get upside down or if your box is broken.
However, There are also some disadvantages in the use of gel batteries: They have to be recharged at low currents and voltages, To avoid the creation of bubbles within the gelified electrolyte, that could permanently damage the battery. For this reason, It is particularly important to avoid the use of traditional rapid loaders for the maintenance of gel batteries.

Battery life

The life time of a battery can vary considerably depending on several factors. The most important, however, They are adequate use and maintenance(load).
Among the main reasons that can cause a premature death of the battery, There are the following:

  • Leave the inactive battery (Sulfatation due to self-discharge).
  • Maintain partially downloaded battery (Progressive sulfation)
  • The battery discharge beyond its limit (Electrode Corrosion) It is usually a 20%.
  • The overload (Destruction of the electrolyte) loading it with a voltage higher than recommended by the manufacturer.

How to prevent the battery from losing its ability.

In housing vehicles most users, Think that with putting a relay to load the battery while traveling this will always be loaded.
But reality is very different, since they exist 3 Load phases and with the alternator we would not complete the absorption stage unless we were driving many hours.

1. Eata Bulk:

In this first stage Current to the battery is supplied at maximum intensity, So the voltage (strain) increase rapidly until it reaches approximately 12,6 V, And then little by little to the first voltage limit. Once this limit is reached The battery is loaded with 80%, From this point the absorption of load current is quickly reduced, We are now at a 14.4v potential according to the battery and alternator.

2. Absorption stage:

In this phase The load current decreases slowly until the battery is loaded to 100%. At this stage we work at the voltage reached at the end of the Bulk stage, so -called Absorption limit. It is important to know the values ​​of the voltages used exactly and always in accordance with the manufacturer's instructions. The purpose of this stage is Recover the electrolyte, that may have been altered in deep discharge processes, So in batteries that have suffered a Prolonged deep discharge, The absorption phase will be longer To make sure to recover the electrolyte completely.

3. Flotation stage:

In this phase the battery is already loaded to 100% And what is done is Provide the necessary current to compensate for self -device, so that it remains at 100%. It works for low and constant potentials.

If the battery intends to be stored, the flotation voltage cannot vary more than one 1% Regarding the recommended by the manufacturer. For liquid batteries it is recommended to provide voltages between 12,9-14 V, although battery uselessness is not recommended for long periods (months). Instead, Gel batteries can be left in a flotation phase for long periods without problems.

4. Equalization stage:

Its purpose is the rise of gas inside the acid (electrolyte) making the solution become homogeneous; This is why it is also called the exemption stage. Thus We prevent that there is no greater density that can cause the sulfaction of the plates. After this stage we get all cells to have the same voltage. The controller can perform this stage every certain period of time, If it is intended to do by hand, it should be carried out if disparity of values ​​in the density of the electrolyte is detected.

To prevent premature sulflation in an installation whatever its use, lights, fridge (The most common) Water pumps, Investors, etc.. It is essential to install a solar panel.

Depending on consumption, We will install a greater or lower panel capacity. Always taking into account, that this must be superior to daily consumption, since we want or not, can do wrong, Some tree shades us, or simply the solar plate is dirty.

Camper with solar panels 100w 12v Claraboya

 

Not only the battery is important

If something has taught us life, Is that it is useless to have the best battery in the world, If we do not take care of it as is due.

Many people read in forums, And in Facebook groups that having the battery connected to the vehicle alternator is enough, Unfortunately this is a very common failure that the only thing that will cause is that with the use that is normally given to the battery, and the short driving periods, This never loads completely, since it does not complete the absorption phase.

That the absorption phase is not completed, makes our battery little by little losing load, since the cells are sulfatting very little by little over time. For that reason, hundreds of batteries die in their first year of life, And when we contact the manufacturer, The battery guarantee denies us because it has not been properly charged.

We strongly recommend the installation of a solar panel, Ideally, cover our energy expenditure and this correctly oversized, But if our pocket does not allow us, We should install at least 20W or 50W to recover the load during the week, While the vehicle is not used.

 

  1. Hola, that you recommend me, an AGM ultracetal battery or a Trojan T105? para a fiat ducato?

    • Hi Dina, The Ultracell are very good brand, I had one during 8 years and very happy with her. But I will also tell you that trojan is the best in acid, But the latter need a breathing tube abroad.
      How many amps you need? What are you going to connect?
      Las 2 They are very good option, My recommendation is that if you are going to buy one of those two, buy the cheapest, and invest in a solar panel,
      The regulator is also very important that it is of good quality, With that you will have the battery always charged which avoids sulfatation.
      Which is what makes most batteries in the camper, Do not load them properly or do it only with the alternator.

Ycomosehace
Logo